FLUKE 117 - Digital multimeter - FLUKE

FLUKE 117 - Digital multimeter - FLUKEFLUKE 117 - Digital multimeter - FLUKEFLUKE 117 - Digital multimeter - FLUKE

FLUKE 117 - Digital multimeter - FLUKEFLUKE 117 - Digital multimeter - FLUKEFLUKE 117 - Digital multimeter - FLUKE

More details

 

FLUKE-117EUR

349,00 € tax excl.
418,80 €tax incl.


Comment faire une demande de devis : Transformer mon panier en devis
Demo

Notes et avis clients

personne n'a posté d'avis encore
dans cette langue
Noter / écrire un commentaire

 

Fluke 113 Digital Multimeter

Notes:
1 every VCHEK voltage ranges are specified in a range between 60% and 100 points. Since the entries below 60 points are not specified, it is possible that normal multimeter TRMS multimeters and other measures show different from zero when the leads are disconnected from a circuit or are shorted circuit.
2 crest factor ≤ 3 at 4000 points, decreasing linearly to 1.5 at full scale.
3 After all voltage measurement, it is necessary to wait 1 minute to maintain the accuracy of ohms, capacitance, diode test and continuity.

 

 

Electrical Multimeter Fluke 114

 

Designed by electricians. Made by Fluke.

Compact multimeter values real effective for electrical troubleshooting. The Fluke 114 is the ideal tool for troubleshooting performance tests. It includes a feature to avoid false readings caused by ghost voltage.

Also remember to check out the Fluke 115 HVAC Multimeter with Temperature Fluke 116 and Fluke microamperes and 117, for electrical multimeter with non-contact voltage.

 

Electrical Multimeter Fluke 114

33 segments, updates 32 times per second
Operating Temperature
-10 ° C to +50 ° C
Storage temperature-40 ° C to +60 ° C
Battery Type9 volt alkaline battery, NEDA 1604A / IEC 6LR61
Battery400 hours in general, without backlight
Range:600.0 mV
Resolution:0.1 mV
Accuracy:± ([% of reading] + [points]): 2.0% + 3
Volts DC
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:60.00 V / 0.01 V
Range / Resolution:600.00 V / 0.1 V
Auto volt
Range:600.0 V
Resolution:0.1 V
Accuracy:2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
Millivolts AC 1True RMS
Range:600.0 mV
Resolution:0.1 mV
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
1 volt AC true RMS
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:60.00 V / 0.01 V
Range / Resolution:600.0 V / 0.1 V
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range:600 Ω
Resolution:1 Ω
Accuracy:Beep power <20 off=""> 250 Ω; detects interruptions or short circuits 500 microseconds or more.
Ohms
Range / Resolution:600.0 Ω / 0.1 Ω
Range / Resolution:6.000 kΩ / 0.001 kΩ
Range / Resolution:60.00 kΩ / 0.01 kΩ
Range / Resolution:600.0 kΩ / 0.1 kΩ
Range / Resolution:6.000 MΩ / 0.001 MΩ
Accuracy:0.9% + 1
Range / Resolution:40.00 MΩ / 0.01 MΩ
Accuracy:1.5% + 2

 

Fluke 115

 

Designed by electricians. Made by Fluke.

MultimeterCompact True RMS for maintenance technicians on site. The Fluke 115 is ideal for a wide variety of testing applications electrical and electronic equipment.

Also remember to check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with temperature and microamps and the Fluke 117, for electrical multimeter with non-contact voltage.

 

Fluke 115

 

 

 

6 kV according to IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital6000 points, updated 4 times per second
Bargraph
33 segments, updates 32 times per second
Operating Temperature
-10 ° C to +50 ° C
Storage temperature
-40 ° C to +60 ° C
Battery Type
9 volt alkaline battery, NEDA 1604A / IEC 6LR61

Battery

400 hours in general, without backlight
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:60.00 V / 0.01 V
Range / Resolution:600.00 V / 0.1 V
Accuracy:± ([% of reading] + [points]): 0.5% + 2
Millivolts True RMS AC 1
Range:600.0 mV
Resolution:0.1 mV
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
1 volt AC true RMS60.00 V / 0.01 V
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:
Range / Resolution:600.0 V / 0.1 V
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range:600 Ω
Resolution:1 Ω
Accuracy:Beep power <20 off=""> 250 Ω; detects interruptions or short circuits 500 microseconds or more.
Ohms
Range / Resolution:600.0 Ω / 0.1 Ω
Range / Resolution:6.000 kΩ / 0.001 kΩ
Range / Resolution:60.00 kΩ / 0.01 kΩ
Range / Resolution:600.0 kΩ / 0.1 kΩ
Range / Resolution:6.000 MΩ / 0.001 MΩ
Accuracy:0.9% + 1
Range / Resolution:40.00 MΩ / 0.01 MΩ
Accuracy:1.5% + 2
Test diodes
Range / Resolution:2.00 V / 0.001 V
Accuracy:0.9% + 2
Capacity
Range / Resolution:1000 nF / 1 nF
Range / Resolution:10.00 uF / 0.01 uF
Range / Resolution:100.0 uF / 0,1 uF
Range / Resolution:9,999 uF / 1 uF
Range / Resolution:100 uF to 1000 uF
Accuracy:1.9% + 2
Range / Resolution:> 1000 uF
Accuracy:5% + 20%
LoZ capacitance
Range:1 nF to 500 uF
Accuracy:10% + 2
True RMS AC current (between 45 Hz and 500 Hz)
Range / Resolution:6.000 A / 0.001 A
Range / Resolution:10.00 A / 0,01 A
Accuracy:1.5% + 3
Continuous overload of 20 amps for 30 seconds max.
DC current measurements
Range / Resolution:6.000 A / 0.001 A
Range / Resolution:10.00 A / 0,01 A
Accuracy:1.0% + 3
Continuous overload of 20 amps for 30 seconds max.
Hz (V or A input) 2
Range / Resolution:99.99 Hz / 0.01 Hz
Range / Resolution:999.99 Hz / 0.1 Hz
Range / Resolution:9.999 kHz / 0.001 kHz
Range / Resolution:50 kHz / 0.01 kHz
Accuracy:0.1% + 2

 

 

HVAC Multimeter Fluke 116 with temperature and microamps

 

Designed by electricians. Made by Fluke.

Compact Multimeter True RMS for troubleshooting of heating, ventilation, air conditioning and refrigeration (HVAC). The meter 116 has been specially designed for professional heating, ventilation, air conditioning and refrigeration (HVAC). It has all the qualities of an HVAC meter including temperature measurement and microamps to quickly resolve problems concerning heating, ventilating, air conditioning (HVAC) and flame detectors.

Also remember to check out the Fluke 114 Electrical Multimeter, the Fluke 115 HVAC Multimeter and Fluke 117, for electrical multimeter with non-contact voltage.

 

 

HVAC Multimeter Fluke 116 with temperature and microamps

 

 

 

Features
Maximum voltage between any terminal and earth
600 V
Protection against overvoltage
6 kV according to IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital6000 points, updated 4 times per second
Bargraph
33 segments, updates 32 times per second
Operating Temperature
-10 ° C to +50 ° C
Storage temperature
-40 ° C to +60 ° C
Battery Type
9 volt alkaline battery, NEDA 1604A / IEC 6LR61
Battery
400 hours in general, without backlight
Range:600.0 mV
Resolution:0.1 mV
Accuracy:± ([% of reading] + [points]): 2.0% + 3
Volts DC
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:60.00 V / 0.01 V
Range / Resolution:600.00 V / 0.1 V
Auto volt
Range:600.0 V
Resolution:0.1 V
Accuracy:2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
Millivolts True RMS AC 1
Range:600.0 mV
Resolution:0.1 mV
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
1 volt AC true RMS
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:60.00 V / 0.01 V
Range / Resolution:600.0 V / 0.1 V
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range:600 Ω
Resolution:1 Ω
Accuracy:Beep power <20 off=""> 250 Ω; detects interruptions or short circuits 500 microseconds or more.
Ohms
Range / Resolution:600.0 Ω / 0.1 Ω
Range / Resolution:6.000 kΩ / 0.001 kΩ
Range / Resolution:60.00 kΩ / 0.01 kΩ
Range / Resolution:600.0 kΩ / 0.1 kΩ
Range / Resolution:6.000 MΩ / 0.001 MΩ
Accuracy:0.9% + 1
Range / Resolution:40.00 MΩ / 0.01 MΩ
Accuracy:1.5% + 2
Test diodes
Range / Resolution:2,000 V / 0,001 V
Accuracy:0.9% + 2
Capacity
Range / Resolution:1000 nF / 1 nF
Range / Resolution:10.00 uF / 0.01 uF
Range / Resolution:100.0 uF / 0,1 uF
Range / Resolution:9,999 uF / 1 uF
Range / Resolution:100 uF to 1000 uF
Accuracy:1.9% + 2
Range / Resolution:> 1000 uF
Accuracy:5% + 20%
LoZ capacitance
Range:1 nF to 500 uF
Accuracy:10% + 2
Temperature 2 (thermocouple type)
Range / Resolution:-40 ° C to 400 ° C / 0.1 ° C
Accuracy:1% + 10 February
Range / Resolution:-40 ° C to 752 ° C / 0.2 ° C
Accuracy:1% + 18 February
True RMS AC μamps (between 45 Hz and 500 Hz)
Range / Resolution:600.0 uA / 0.1 uA
Accuracy:1.0% + 2
μamps DC
Range / Resolution:600.0 uA / 0.1 uA
Accuracy:1.0% + 2
Hz (V or A input) 2
Range / Resolution:99.99 Hz / 0.01 Hz
Range / Resolution:999.99 Hz / 0.1 Hz
Range / Resolution:9.999 Hz / 0.001 Hz
Range / Resolution:50.00 Hz / 0.01 Hz
Accuracy:0.1% + 2

Mechanical & General Specifications
Dimensions
Height:167 x 84 x 46 mm
Weight
550 g
Warranty
3 years

 

 

 

Fluke 117 with non-contact voltage for electrical

 

 

 

 

 

Fluke 117 with non-contact voltage for electrical

Digital6000 points, updated 4 times per second
Bargraph
33 segments, updates 32 times per second
Operating Temperature
-10 ° C to +50 ° C
Storage temperature
-40 ° C to +60 ° C
Battery Type
9 volt alkaline battery, NEDA 1604A / IEC 6LR61
Battery
400 hours in general, without backlight

Specifications for accuracy
DC millivolts
Range:600.0 mV
Resolution:0.1 mV
Accuracy:± ([% of reading] + [points]): 2.0% + 3
Volts DC
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:60.00 V / 0.01 V
Range / Resolution:600.00 V / 0.1 V
Auto volt
Range:600.0 V
Resolution:0.1 V
Accuracy:2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
Millivolts True RMS AC 1
Range:600.0 mV
Resolution:0.1 mV
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
1 volt AC true RMS
Range / Resolution:6.000 V / 0.001 V
Range / Resolution:60.00 V / 0.01 V
Range / Resolution:600.0 V / 0.1 V
Accuracy:1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range:600 Ω
Resolution:1 Ω
Accuracy:Beep power <20 off=""> 250 Ω; detects interruptions or short circuits 500 microseconds or more.

Avis

Soyez le premier à donner votre avis !

Accessoires

30 other products in the same category:

Customers who bought this product also bought: