- 6.5 digit resolution
- Basic Accuracy DC voltage of 0.0024%
- Dual Display
- Current range of 100 uA to 10 A, up to 100 pA resolution
- Wide range of resistance from 10 Ω to 1 GΩ, up to 10 μΩ resolution
- Measurement technique on 4 ohms son 2x4
- Both models measure frequency and period
- The Fluke 8846A also measures the capacity and temperature
- USB memory port (8846A)
- Emulation of the Fluke 45 and Agilent 34401A
- Graphic Display
- Paperless recorder mode Trendplot ™, statistics, histogram
- 1000 V CAT I, CAT II 600 V
|
Multimeters precision 6.5 digit Fluke 8845A and 8846A precision and versatility to handle your most demanding measurements on test stands and systems. Powerful and feature-rich, they still remain remarkably friendly.
These devices integrate all the functions you'd normally expect from a versatile digital multimeter, which measures the voltageresistance and current. Accuracy of 0.0024% basic DC voltage, scale current of 10 A and their wide range in resistance offer an unparalleled range of measurement.
You can also use the 8845A and 8846A to measure frequency and period. The Fluke 8846A also measures temperature and capacity. The functions of a meter, a capacitance meter and a thermometer are thus combined for unparalleled versatility. Graphics modes further enhance the utility of these multimeters, including paperless recorder mode TrendplotTM, statistics and histograms, many features not found on other multimeters.
Of course, these devices are also durable and reliable, like all Fluke. With their unique combination of features and performance, the 8845A and 8846A are more unique for a wide variety of applications including manufacturing controls, research and development and maintenance.
Dual display and graphics capabilities versatile
The dual display of unique 8845A/8846A lets you simultaneously measure two parameters ofsame signal on a single cord. To highlight the problems of signal quality such as drift, intermittent events and instability, view the data as a trend plot in real time or in a histogram. You will not find such analytical display capabilities on any other device in the same category.
Measurement of 4 with only two cords son
The patented split terminal jacks for 2x4 ohmmeter function can perform precision measurements 4 son using only two leads instead of four. For a special test lead can connect. You get excellent resolution and high precision while enjoying the comfort of a single pair of cords.
Many connectors for maximum flexibility
The 8845A/8846A can connect to a computer via various interfaces provided on both models (serial, Ethernet and IEEE-488). The Fluke 8846A comes with a USB port for easy data transfer to PC or from it via a portable USB memory.
FlukeView ® and drivers bring PC power and compatibility with applications.
FlukeView Forms increases the power of your Fluke tool by enabling you to document, store and analyze measures, individually or jointly, then convert them into professional-quality documents. Record the measurements in real time directly in connection with a PC or store, view and share data in forms, graphics and interactive whiteboards. Create custom business documents, you can print or attach to an email. FlukeView Forms comes with standard forms easy to use.
Pilot program, information and DLL files are also included so that your test system up and running as quickly as possible.
FlukeView ® Forms Basic
The 8845A/8846A comes with a free copy of FlukeView Basic. Transfer data points of your instrument to your PC and use the two standard forms, not customizable to display your records in a table or graph. If you want to enjoy a wider choice of forms or use FlukeView ® Forms Designer to customize your forms, go to version 3.0 FlukeView ® Forms using FVF-UG.
Emulation of the Fluke 45 and Agilent 34401A
8845A/8846A emulate the operation and programming of the Fluke 45 and Agilent 34401. The emulation speeds learning and facilitates the integration of Fluke 8845A or 8846A into existing test systems.
Fluke assistance as added value
Like all Fluke products, the 8845A/8846A are built for years of loyal service. If a re-calibration or repair should be necessary, however, you may turn to our network of direct services and approved, strategically located around the world. Each center offers a full range of support services.
| Precision and versatility for bench testing and systems - 6.5 digit resolution
- Basic Accuracy DC voltage of 0.0024%
- Dual Display
- Current range of 100 uA to 10 A, up to 100 pA resolution
- Wide range of resistance from 10 Ω to 1 GΩ, up to 10 μΩ resolution
- Measurement technique on 4 ohms son 2x4
- Both models measure frequency and period
- The Fluke 8846A also measures the capacity and temperature
- USB memory port (8846A)
- Emulation of the Fluke 45 and Agilent 34401A
- Graphic Display
- Paperless recorder mode Trendplot ™, statistics, histogram
- 1000 V CAT I, CAT II 600 V
|
Multimeters precision 6.5 digit Fluke 8845A and 8846A precision and versatility to handle your most demanding measurements on test stands and systems. Powerful and feature-rich, they still remain remarkably friendly. These devices integrate all the functions you'd normally expect from a versatile digital multimeter, which measures voltage, resistance and current. Accuracy of 0.0024% basic DC voltage, scale current of 10 A and their wide range in resistance offer an unparalleled range of measurement. You can also use the 8845A and 8846A to measure frequency and period. The Fluke 8846A also measures temperature and capacity. The functions of a meter, a capacitance meter and a thermometer are thus combined for unparalleled versatility. Graphics modes further enhance the utility of these multimeters, including paperless recorder mode TrendplotTM, statistics and histograms, many features not found on other multimeters. Of course, these devices are also durable and reliable, like all Fluke. With their unique combination of features and performance, the 8845A and 8846A are more unique for a wide variety of applications including manufacturing controls, research and development and maintenance. |

Dual display and graphics capabilities versatile The dual display of unique 8845A/8846A lets you simultaneously measure two parameters of the same signal on a single cord. To highlight the problems of signal quality such as drift, intermittent events and instability, view the data as a trend plot in real time or in a histogram. You will not find such analytical display capabilities on any other device in the same category. Measurement of 4 with only two cords son The patented split terminal jacks for 2x4 ohmmeter function can perform precision measurements 4 son using only two leads instead of four. For a special test lead can connect. You get excellent resolution and high precision while enjoying the comfort of a single pair of cords. Many connectors for maximum flexibility The 8845A/8846A can connect to a computer via various interfaces provided on both models (serial, Ethernet and IEEE-488). The Fluke 8846A comes with a USB port for easy transferdata to a PC or from it via a portable USB memory. FlukeView ® and drivers bring PC power and compatibility with applications. FlukeView Forms increases the power of your Fluke tool by enabling you to document, store and analyze measures, individually or jointly, then convert them into professional-quality documents. Record the measurements in real time directly in connection with a PC or store, view and share data in forms, graphics and interactive whiteboards. Create custom business documents, you can print or attach to an email. FlukeView Forms comes with standard forms easy to use. Pilot program, information and DLL files are also included so that your test system up and running as quickly as possible. FlukeView ® Forms Basic The 8845A/8846A comes with a free copy of FlukeView Basic. Transfer data points of your instrument to your PC and use the two standard forms, not customizable to display your records in a tableor graphic. If you want to enjoy a wider choice of forms or use FlukeView ® Forms Designer to customize your forms, go to version 3.0 FlukeView ® Forms using FVF-UG. Emulation of the Fluke 45 and Agilent 34401A 8845A/8846A emulate the operation and programming of the Fluke 45 and Agilent 34401. The emulation speeds learning and facilitates the integration of Fluke 8845A or 8846A into existing test systems. Fluke assistance as added value Like all Fluke products, the 8845A/8846A are built for years of loyal service. If a re-calibration or repair should be necessary, however, you may turn to our network of direct services and approved, strategically located around the world. Each center offers a full range of support services. |
Technical Specifications | Display | | Resolution | | Voltage DC | Ranges: | 100 mV to 1000 V | Max. Resolution: | 100 nV | Accuracy: | 8845A: 0.0035 + 0.0005 | | 8846A: 0.0024 + 0.0005 |
| AC voltage | Ranges: | 8845A: 100 mV to 750 V | | 8846A: 100 mV to 1000 V | Max. Resolution: | 100 nV | Accuracy: | 8845A: 0.06 + 0.03 | | 8846A: 0.06 + 0.03 | Frequency: | 3 Hz to 300 kHz |
| Resistance | 2x4 son: | Yes | Ranges: | 8845A: 100 Ω to 100 MW | | 8846A: 10 Ω to 1 GΩ | Max. Resolution: | 8845A: 100 μΩ | | 8846A: 10 μΩ | Accuracy: | 8845A: 0.010 + 0.001 | | 8846A: 0.010 + 0.001 |
| DC | Ranges: | 100 uA to 10 A | Max. Resolution: | 100 pA | Accuracy: | 0,050 0,005 + |
| AC | Ranges: | 8845A: 10 mA to 10 A | | 8846A: 100 mA to 10 A | Max. Resolution: | 8845A: 10 nA | | 8846A: 100 pA | Accuracy: | 0,10 + 0,04 | Frequency: | 3 Hz to 10 kHz |
| Freq / period | Ranges: | 8845A: 3 Hz to 300 kHz | | 8846A:3 Hz to 1 MHz | Max. Resolution: | 1 μHz | Accuracy: | 0.01% |
| Diode test and continuity | | Capacity | Ranges: | 8846A: 1 nF to 0.1 F | Max. Resolution: | 8846A: 1 pF | Accuracy: | 8846A: 1% |
| Temperature | Type: | 8846A: Platinum RTD | Ranges: | 8846A: -200 ° C to +600 ° C | Max. Resolution: | 8846A: 0.01 ° | Accuracy: | 8846A: 0.06 ° |
| Math Functions | | NULL, Min / Max / Average, Standard deviation | dB / dBm: | Yes |
| Advanced Features | Statistics / Histogram: | Yes | TrendPlot: | Yes | Test limits: | Yes |
| Inputs / Outputs | USB memory: | 8846A: USB Port Memory | Real time clock: | 8846A: Yes | Interfaces: | RS-232, IEE-488.2, Ethernet, USB (with optional adapter) | Languages / programming modes: | 8846A: SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 |
|
General Characteristics | Weight | | Dimensions | | Security | | Designed to meet IEC 61010-1 2000-1 ANSI/ISA-S82.01-1994, CSA C22.2 No. 1010.1-92 CAT I 1000 V, CAT II 600 V |