FLUKE 561 - Digital Thermometer contact and infrared
FLUKE 561 - Digital Thermometer contact and infraredFLUKE 561 - Digital Thermometer contact and infraredFLUKE 561 - Digital Ther
Recipient :
* Required fields
or Cancel
FLUKE 561 - Digital Thermometer contact and infraredFLUKE 561 - Digital Thermometer contact and infraredFLUKE 561 - Digital Ther
FLUKE-561
within 2 weeks
Warning: Last items in stock!
Availability date:
The Fluke 561 infrared thermometer allows you to measure the ambient temperature or touch the way that suits you best. Use the infrared thermometer to measure objects instantly elevated temperature, movement, power or inaccessible. Check the engines, isolation, circuit breakers, radiant heating, pipes, corroded connections and cables. You can even check the temperature of pipes or other objects difficult to reach without a ladder. Use the Velcro ® pipe probe's handy Fluke 561 or plug in a mini-connector thermocouple type K is already in your possession for measuring extreme heat or internal.
Temperature range -40 ° C to 550 ° C
Display resolution 0.1 ° measurement
12:1 optical resolution
Three simple emissivity selector positions: Low (0.3), medium (0.7), high (0.95)
Readability (based on a temperature ± 1.0% of reading or ± 1 ° C, whichever is greater; below
Operating ambient of 23 ° C to 25 ° C) 0 ° C ± 1 ° C ± 1 ° / 1 °
Response time 500 ms (95% of reading)
Repeatability ± 0.5% of reading or ± 1 ° C, whichever is higher
Spectral band 8 microns to 14 microns
Laser sighting system to a point
Case Laser The laser shuts off when the ambient temperature exceeds 40 ° C.
Laser Power Meets Class 2 (II) output <1 mw="" wavelength="" 630-670="" nm="" br=""> Relative humidity 10% to 90%noncondensing, at <30 c="" br=""> PAlimentation 2 AA batteries (alkaline or NiCd)
Display Hold 7 seconds
Yes Backlit display, LCD dual display (current temperature and MAX / MIN / DIF / TC-K), battery
low indicator ° C / ° F and scanning options / Maintenance
Operating temperature 0 ° C to 50 ° C
Storage temperature -20 ° C to 65 ° C
Temperatures MAX, MIN, DIFF Yes
Entry for mini-connector thermocouple type K Yes, compatible with type K probes
Velcro pipe probe, thermocouple type K Yes, in a temperature range from 0 ° C to 100 ° C with an accuracy
of ± 2.2 ° C
Measurement Guide Yes
Accessoires
30 other products in the same category:
TESTO 805 - thermomètre infrarouge - 05608051 TESTO 805 - thermomètre infrarouge - 05608051 TESTO...
TESTO 805 - thermomètre infrarouge - 05608051 TESTO 805 - thermomètre infrarouge - 05608051 TESTO...
Fluke 572-2 - Thermomètre infrarouge haute température Fluke 572-2 - Thermomètre infrarouge haute...
Fluke 566 - infrared thermometer and contactFluke 566 - infrared thermometer and contactFluke 566...