Fluke 62 - infrared thermometer with laser sight

Fluke 62 - infrared thermometer with laser sightFluke 62 - infrared thermometer with laser sightFluke 62 - infrared thermometer

Fluke 62 - infrared thermometer with laser sightFluke 62 - infrared thermometer with laser sightFluke 62 - infrared thermometer

More details

 

FLUKE-62 MAX

underway replenishment

135,00 € tax excl.
162,00 €tax incl.


Comment faire une demande de devis : Transformer mon panier en devis
Demo

Notes et avis clients

personne n'a posté d'avis encore
dans cette langue
Noter / écrire un commentaire

 

  • Laser sighting system to a point
  • Better accuracy in its class: 1% of reading
  • Maintaining the temperature display for 7 seconds
  • Simultaneous display of current and MAX measurements
  • Backlit display for use in the dark
  • Comfortable ergonomic handle with rubber coating for increased durability
  • Carrying case included
  • Robust design and award-winning
  • Wide temperature range from -30 ° C and 500 ° C
Features
Backlit display for use in the dark
Fluke 61Yes
Fluke 62Yes
Fluke 63Yes
Fluke 66Yes
Fluke 68Yes
Conservation measures
Fluke 61Yes
Fluke 62Yes
Fluke 63Yes
Fluke 66Yes
Fluke 68Yes
Range
Fluke 61-18 ° C to 275 ° C (-0 ° F to 525 ° F)
Fluke 62-30 ° C to 500 ° C (-20 ° F to 932 ° F)
Fluke 63-32 ° C to 545 ° C (-25 ° F to 999 ° F)
Fluke 66-32 ° C to 600 ° C (-25 ° F to 1100 ° F)
Fluke 68-32 ° C to 760 ° C (-25 ° to 1400 ° F)
MIN / MAX / AVG
Fluke 61N / A
Fluke 62MAX
Fluke 63MAX
Fluke 66All
Fluke 68All
Datalogging
Fluke 61N / A
Fluke 62N / A
Fluke 63N / A
Fluke 66Yes
Fluke 68Yes
Distance to spot ratio
Fluke 618:01
Fluke 6210.1 to 80% of energy
Fluke 6312:01
Fluke 6630:01:00
Fluke 6850:01:00
High / low alarm
Fluke 61N / A
Fluke 62N / A
Fluke 63Yes
Fluke 66Yes
Fluke 68Yes
Optional RTD probe (contact temperature measurement)
Fluke 61N / A
Fluke 62N / A
Fluke 63N / A
Fluke 66Yes
Fluke 68Yes
Emissivity
Fluke 61Fixed at 0.95
Fluke 62Fixed at 0.95
Fluke 63Fixed at 0.95
Fluke 66Digital setting (0.1 to 1.0 in increments of 0.01)
Fluke 68Digital setting (0.1 to 1.0 in increments of 0.01)
Measuring accuracy
Fluke 61
-18 ° C to -1 ° C (0 ° F to 30 ° F)± 3 ° C (5 ° F)
above -1 ° C (30 ° F) to 275 ° C (525 ° F)± 2% of reading or 2 ° C (3.5 ° F)
(With the instrument stable between 23 ° C and 25 ° C)
Fluke 63, 66, 68
-32 ° C to -26 ° C (-25 ° F to -15 ° F):± 3 ° C (± 5 ° F)
-26 ° C to -18 ° C (-15 ° F to 0 ° F):± 2.5 ° C (± 4 ° F)
-18 ° C to 23 ° C (-0 ° F to 73 ° F):± 2 ° C (± 3 ° F)
For targets above 23 ° C (73 ° F): ± 1% of reading or ± 1 ° C (± 2 ° F), whatever the highest value

 

 

 

 

 

 

Avis

Soyez le premier à donner votre avis !

Accessoires

30 other products in the same category:

Customers who bought this product also bought: