Fluke 568 - contact thermometer and infrared thermometer

Fluke 568 - contact thermometer and infrared thermometerFluke 568 - contact thermometer and infrared thermometerFluke 568 - cont

Fluke 568 - contact thermometer and infrared thermometerFluke 568 - contact thermometer and infrared thermometerFluke 568 - cont

More details

 

FLUKE-568

underway replenishment

773,00 € tax excl.
927,60 €tax incl.


Comment faire une demande de devis : Transformer mon panier en devis
Demo

Notes et avis clients

personne n'a posté d'avis encore
dans cette langue
Noter / écrire un commentaire

With a simple interface (6 languages), based menus and three buttons, digital laser thermometers Fluke 568 and 566 simplify the measurements, even the most complex. Fly through the advanced functions, using a few buttons to set the emissivity to store data or to enable and disable alarms.

From an ergonomic design, simple and solid, thermometers contact and contactless combined Fluke 568 and 566 are resistant to industrial environments, electrical and mechanical harshest. These tools are performing better than other IR thermometers (or pyrometers), and allow you to work more efficiently in more applications.

PRODUCT SPECIFICATIONS
Range of infrared temperature
2.35833 E 14-40 ° C to 650 ° C (-40 ° F to 1202 ° F)
2.36667 E 14-40 ° C to 800 ° C (-40 ° F to 1472 ° F)
Precision Infrared
<0 c="" 32="" f="" :="" 1="" 0="" 2="" or="" br=""> > 0 ° C (32 ° F): ± 1% or ± 1.0 ° C (± 2.0 ° F), whichever is higher
Display resolution
0.1 ° C / 0.1 ° F
Infrared spectral response
8 microns to 14 microns
Infrared response time
<500 ms="" td="">
Range of inlet temperatures of the thermocouple type K
-270 ° C to 1372 ° C (-454 ° F to 2501 ° F)
Input accuracy of the thermocouple type K
-270 ° C to -40 ° C:± (1 ° C + 0.2 ° / 1 ° C) (-454 ° F to -40 ° F: ± (2 ° + 0.2 ° F / 1 ° F))
-40 ° C to 1372 ° C:± 1% or 1 ° C (-40 ° F to 2501 ° F: ± 1% or 2 ° F), whichever is higher
D: S (optical)
566:30:1
568:50:1
Laser sighting system
Point laser compliant Class 2 (II) output <1 mw="" 630="" nm="" to="" 670="" td="">
Minimum size of point
19 mm
Emissivity setting
Integrated picture of common materials or digital adjustment of 0.10 to 1.00 in increments of 0.01
Data storage with time stamp
566:20 points
568:99 points
PC interface cable
566:No
568:USB 2.0 with FlukeView ® Forms
Low alarms and / or High
Sound or visual color
Min / Max / Avg / Dif
Yes
Display
Matrix of 98 x 96 pixels with function menus
Backlight
Two levels, normal and extra bright for darker environments
Trigger lock
Yes
Switchable between Celsius and Fahrenheit
Yes
Food
2.35833 E 142 x LR6
2.36667 E 142 LR6 batteries and USB connection when used with a PC
Battery
Continuous use:12 hours with laser and backlight on, 100 hours with laser and backlight off
Temperature FUNCTIONINGt
0 ° C to 50 ° C
Storage temperature
-20 ° C to 60 ° C (-4 ° F to 140 ° F)
Range of bead probe thermocouple type K
-40 ° C to 260 ° C (-40 ° F to 500 ° F)
Accuracy of the bead probe thermocouple type K

± 1.1 ° C (2.0 ° F) 0 ° C to 260 ° C (32 ° F to 500 ° F), and ± 1.1 ° C (2.0 ° F) -40 ° C 0 ° C (-40 ° F to 32 ° F)

 