For increased power calibration

The Process Calibrator Fluke 726 Precision Multifunction designed specifically for process applications to ensure a high working ability, great power and precision calibration foolproof. The Fluke 726 can measure and all process parameters, but also calibrate almost anything. In addition, it interprets the results of calibration without the need for computer and can store measurement data for later analysis.

 

  • More accurate and better performance for generating calibration accuracy 0.01%
  • Two independent channels, measurement, generation and simultaneous display of process signals
  • Measure volts, mA, RTDs, thermocouples, frequency and resistance to test sensors and transmitters
  • Source / simulate volts, mA, thermocouples, RTDs, frequency and pressure to calibrate transmitters
  • * Measure or pressure by any of 29 Fluke pressure modules 700Pxx
  • Generation of current (mA) with simultaneous pressure measurement to conduct valve and tests / P
  • Test pressure switchBuilt to capture the setting, reset and deadband of a switch
  • Possibility of storage of 8 calibration results for later analysis
  • Calculating percentage error of the transmitter and interpretation of calibration results without a calculator
  • Running fast linearity tests with features of stepper automatic and automatic ramp
  • Power transmitters during test (24 V) with simultaneous mA measurement
  • Storing frequently used test setups for later use
  • Frequency counter and method of generation of pulse trains of frequency for more precise control of flow
  • HART mode adding a resistance of 250 ohms measurement and generation of mA to ensure full compatibility with HART
  • Customizing curves RTDs, add calibration constants for probes RTDs certified in order to obtain more accurate temperature measurements
  • New design incorporating a voltage input protection for increased reliability
  • 3 years warranty

 

 

For increased power calibration

The Process Calibrator Fluke 726 Precision Multifunction designed specifically for process applications to ensure a high working ability, great power and precision calibration foolproof. The Fluke 726 can measure and all process parameters, but also calibrate almost anything. In addition, it interprets the results of calibration without the need for computer and can store measurement data for later analysis.

F-726_03a_200p.jpg

 

  • More accurate and better performance for generating calibration accuracy 0.01%
  • Two independent channels, measurement, generation and simultaneous display of process signals
  • Measure volts, mA, RTDs, thermocouples, frequency and resistance to test sensors and transmitters
  • Source / simulate volts, mA, thermocouples, RTDs, frequency and pressure to calibrate transmitters
  • * Measure or pressure by any of 29 Fluke pressure modules 700Pxx
  • Generation of current (mA) with simultaneous pressure measurement to conduct valve and tests / P
  • Test pressure switch built to capture the setting, reset and deadband of a switch
  • Possibility of storage of 8 calibration results for later analysis
  • Calculating percentage error of the transmitter and interpretation of calibration resultswithout computer
  • Running fast linearity tests with features of stepper automatic and automatic ramp
  • Power transmitters during test (24 V) with simultaneous mA measurement
  • Storing frequently used test setups for later use
  • Frequency counter and method of generation of pulse trains of frequency for more precise control of flow
  • HART mode adding a resistance of 250 ohms measurement and generation of mA to ensure full compatibility with HART
  • Customizing curves RTDs, add calibration constants for probes RTDs certified in order to obtain more accurate temperature measurements
  • New design incorporating a voltage input protection for increased reliability
  • 3 years warranty

* Pump pressure required

 

recision measuring
Voltage DC
30.000 V0.02% + 2 points (upper display)
30.000 V0.02% + 2 points (lower display)
100.00 mV0.01% + 2 points
of -10.00 mV to 75.00 mV0.025% + 1 point (via TC connector)
DC
24.000 mA0.01% + 2 points
Resistance
from 0.0 Ω to 4 000.0 Ω+ / - 0.015%
Frequency
2.0 1 000.0 CPM CPM0.05% + 1 point
from 1.0 Hz to 1 000.0 Hz0.05% + 0.1 Hz
from 1.0 kHz to 15.0 kHz0.05% + 0.1 kHz
from 10.0 kHz to 15.0 kHz0.05% + 1 point
Sensitivity1 Vpp minimum
Pressure
Accuracyof 0.025% of range using any of 29 pressure modules.
(For detailed specifications, refer to pressure modules in the Options and accessories)
Modules available for differential, gage, absolute, double and high, and the void.
Source Accuracy
Voltage DC
100.00 mV0.01% + 2 points
10.000 V0.01% + 2 points
of -10.00 mV to 75.00 mV0.025% + 1 point (via TC connector)
DC
24.000 mA (Gen.)0.01% + 2 points
24.000 mA (simulation)0.01% + 2 points
Resistance
Rangefrom 5 Ω to 400 Ω
from 5 Ω to 400 Ω
from 400 Ω to 1500 Ω
of 1500 Ω to 4000 Ω
AccuracyPercentage of reading + floor
0.015% + 0.1 Ω
0.015% + 0.05 Ω
0.015% + 0.5 Ω
0.015% + 0.5 Ω
Excitation current0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Frequency
2.0 1 000.0 CPM CPM0.05%
from 1.0 Hz to 1 100.0 Hz0.05%
of 1.00 kHz to 10.00 kHz0.25%
from 10.0 kHz to 15.0 kHz0.5%
Waveform:square wave 5 Vpp, offset by -0.1 V
RTDs and thermocouples
Precision measurement and generation:
Cu101.8 ° C
NI-1200.15 ° C
PT-100 (385)0.25 ° C
PT-100 (392)0.15 ° C
PT-100 (391-JIS)0.25 ° C
PT-200 (385)0.75 ° C
PT-500 (385)0.35 ° C
PT-1000 (385)0.15 ° C
Resolution:0.01 ° C
J:0.4 ° C
K:0.5 ° C
T:0.4 ° C
E:0.4 ° C
A:1.4 ° C
S:1.4 ° C
B:1.4 ° C
L:0.45 ° C
U:0.45 ° C
N:0.6 ° C
XK:0.4 ° C
BP:1.1 ° C
ResolutionJ, K, T, E, L, N, U: 0.1 ° C, 0.1 ° F, B, R, S: 1 ° C, 0.1 ° F
Specifications
Ramp functions
Generation functions:Voltage, current, resistance, frequency, temperature
RampsSlow ramp, fast ramp, levels of 25%
Loop Power Function
Voltage:24 V
Accuracy:10%
Maximum current:22 mA, protected against short circuits
Step Functions
Generation functions:Voltage, current, resistance, frequency, temperature
Levels25% of the range, 100% of range
Environmental Specifications
Operating Temperature
-10 ° C to +55 ° C
Storage temperature
-20 ° C to +71 ° C
Operating Altitude
3000 m
Safety Features
Compliance with safety standards
Certified EN 61010-1:1993, ANSI / ISA S82.01-1994, CAN / CSA C22.2 No. 1010.1:1992
Mechanical & General Specifications
Dimensions
200 x 96 x 47 mm
Weight
650 g
Batteries
4 AA alkaline batteries
Battery Replacement
Separate battery compartment, accessible without breaking calibration seal
Side port connections
Pressure module connector, also used for programming real-time remote

 

 